ID number Name Mass Model Power supply Cutoff frequency (-3 dB) Measuring standard Minimum operating temperature Min. operating temperature (moving cable) Connecting direction Permissible axial motion of measured shaft Mechanical device version Shock 6 ms (EN 60068-2-27) Line count Electrical connection System accuracy Total current without load Min. operating temperature (stationary cable) Measuring method Shaft type Vibration 55 Hz to 2000 Hz (EN 60068-2-6) Degree of protection Moment of inertia of the rotor (shaft) Starting torque at 20 °C Product version Cable type Mechanical permissible speed Cable length Nominal increment of reference marks Name Flange version Natural frequency Shaft diameter Shaft Output signal Form of housing Pin configuration Fault detection signal Max. scanning frequency Special characteristics, rotational encoders Company identification Operating temperature Data interface Positions per revolution Interface Safety concept Max. mechanical permissible speed/rotational speed Output code Number of clock pulses for position value transfer Accuracy grade Type of packaging Number of signal periods Number of scanning fields Positions per revolution 2 Reference mark End block Measuring length Number of scanning units Measuring step 1 Thermal coefficient of linear expansion Limit switch 2 ASIC Ausführung und Version Vibration resistance Shock and impact load Fastening type Counting direction Limit switch Grating period Special characteristics, scanning head Reference pulse width Internal clock frequency Reversal hysteresis Coupling version Length of additional cable Maximum rotational speed Basic ID number Further reference marks Reference mark position Special characteristics, linear encoder Product family Permissible cable length (with HEIDENHAIN cable) Reference temperature Maximum operating temperature Shock 11 ms (EN 60068-2-27) Signal period Type of guide Plunger actuation Position of plunger at rest Operating attitude Maximum position error per signal period Mechanically permissible lateral force Electrically permissibly traversing speed Special characteristics, length gauge Compressed air Drum outside diameter Accuracy of the graduation Measuring principle Angle for absolute reference Drum inside diameter Minimum edge separation Mechanically permissible traversing speed Cable type 2 Measuring step Clock frequency Ordering designation Typical current consumption without load Power consumption Calculation time tcal Geometry of drum Display Encoder interface Encoder connection Number of encoder inputs User interface Position value at beginning of ML Electrical connection 2 Electrical permissible speed
325392-03 CT 2501 520 g 2501 DC 5 V (±5 %) DIADUR phase grating graduation on Zerodur glass ceramic ≥ +10 °C Connector M23, male, 9-pin ± 0.1 µm (at 19 °C to 21 °C) ≤ 180 mA incremental ≤ 100 m/s² IP 50 (EN 60529) Incremental length gauges with ball-bush guided plunger PUR Ø 4.5 mm 1.5 m CT 04 D295051 01 HEIDENHAIN +10/+40 °C 11 µApp 0.1 µm one (1.7 mm below upper stop) 25 mm Clamping shank D = 16 mm 4 µm 1.5 m HEIDENHAIN-CERTO ≤ 30 m 20 °C ≤ +40 °C ≤ 1000 m/s² 2 µm ball guide by motor any ± 0.02 µm ≤ 0.5 N ≤ 24 m/min .. none 01 PUR Ø 4.5 mm
325392-04 CT 2502 480 g 2502 DC 5 V (±5 %) DIADUR phase grating graduation on Zerodur glass ceramic ≥ +10 °C Connector M23, male, 9-pin ± 0.1 µm (at 19 °C to 21 °C) ≤ 120 mA incremental ≤ 100 m/s² IP 50 (EN 60529) Incremental length gauges with ball-bush guided plunger PUR Ø 4.5 mm 1.5 m CT 04 D295051 01 HEIDENHAIN +10/+40 °C 11 µApp 0.1 µm one (1.7 mm below upper stop) 25 mm Clamping shank D = 16 mm 4 µm w/o cable HEIDENHAIN-CERTO ≤ 30 m 20 °C ≤ +40 °C ≤ 1000 m/s² 2 µm ball guide via coupling with moving machine part any ± 0.02 µm ≤ 0.5 N ≤ 24 m/min .. none .. w/o cable
329352-01 CT 6001 700 g 6001 DC 5 V (±5 %) DIADUR phase grating graduation on Zerodur glass ceramic ≥ +10 °C Connector M23, male, 9-pin ± 0.1 µm (at 19 °C to 21 °C) ≤ 180 mA incremental ≤ 100 m/s² IP 50 (EN 60529) Incremental length gauges with ball-bush guided plunger PUR Ø 4.5 mm 1.5 m CT 04 D295051 01 HEIDENHAIN +10/+40 °C 11 µApp 0.1 µm one (1.7 mm below upper stop) 60 mm Screw-on surface 4 µm 1.5 m HEIDENHAIN-CERTO ≤ 30 m 20 °C ≤ +40 °C ≤ 1000 m/s² 2 µm ball guide by motor any ± 0.02 µm ≤ 0.5 N ≤ 24 m/min .. none 01 PUR Ø 4.5 mm
329352-02 CT 6002 640 g 6002 DC 5 V (±5 %) DIADUR phase grating graduation on Zerodur glass ceramic ≥ +10 °C Connector M23, male, 9-pin ± 0.1 µm (at 19 °C to 21 °C) ≤ 120 mA incremental ≤ 100 m/s² IP 50 (EN 60529) Incremental length gauges with ball-bush guided plunger PUR Ø 4.5 mm 1.5 m CT 04 D295051 01 HEIDENHAIN +10/+40 °C 11 µApp 0.1 µm one (1.7 mm below upper stop) 60 mm Screw-on surface 4 µm w/o cable HEIDENHAIN-CERTO ≤ 30 m 20 °C ≤ +40 °C ≤ 1000 m/s² 2 µm ball guide via coupling with moving machine part any ± 0.02 µm ≤ 0.5 N ≤ 24 m/min .. none .. w/o cable
653225-01 CT 2501 520 g 2501 DC 5 V (±5 %) DIADUR phase grating graduation on Zerodur glass ceramic ≥ +10 °C D-sub connector, 2-row, with locking screws, with integrated electronics, coated, male, 15-pin ± 0.1 µm (at 19 °C to 21 °C) ≤ 180 mA incremental ≤ 100 m/s² IP 50 (EN 60529) Incremental length gauges with ball-bush guided plunger PUR Ø 4.5 mm 1.5 m CT 2D D330979 01 HEIDENHAIN +10/+40 °C 11 µApp 0.1 µm one (1.7 mm below upper stop) 25 mm Clamping shank D = 16 mm 4 µm 1.5 m HEIDENHAIN-CERTO ≤ 30 m 20 °C ≤ +40 °C ≤ 1000 m/s² 2 µm ball guide by motor any ± 0.02 µm ≤ 0.5 N ≤ 24 m/min .. none 01 PUR Ø 4.5 mm
653228-01 CT 2502 480 g 2502 DC 5 V (±5 %) DIADUR phase grating graduation on Zerodur glass ceramic ≥ +10 °C D-sub connector, 2-row, with locking screws, with integrated electronics, coated, male, 15-pin ± 0.1 µm (at 19 °C to 21 °C) ≤ 120 mA incremental ≤ 100 m/s² IP 50 (EN 60529) Incremental length gauges with ball-bush guided plunger PUR Ø 4.5 mm 1.5 m CT 2D D330979 01 HEIDENHAIN +10/+40 °C 11 µApp 0.1 µm one (1.7 mm below upper stop) 25 mm Clamping shank D = 16 mm 4 µm w/o cable HEIDENHAIN-CERTO ≤ 30 m 20 °C ≤ +40 °C ≤ 1000 m/s² 2 µm ball guide via coupling with moving machine part any ± 0.02 µm ≤ 0.5 N ≤ 24 m/min .. none .. w/o cable
653229-01 CT 6001 700 g 6001 DC 5 V (±5 %) DIADUR phase grating graduation on Zerodur glass ceramic ≥ +10 °C D-sub connector, 2-row, with locking screws, with integrated electronics, coated, male, 15-pin ± 0.1 µm (at 19 °C to 21 °C) ≤ 180 mA incremental ≤ 100 m/s² IP 50 (EN 60529) Incremental length gauges with ball-bush guided plunger PUR Ø 4.5 mm 1.5 m CT 2D D330979 01 HEIDENHAIN +10/+40 °C 11 µApp 0.1 µm one (1.7 mm below upper stop) 60 mm Screw-on surface 4 µm 1.5 m HEIDENHAIN-CERTO ≤ 30 m 20 °C ≤ +40 °C ≤ 1000 m/s² 2 µm ball guide by motor any ± 0.02 µm ≤ 0.5 N ≤ 24 m/min .. none 01 PUR Ø 4.5 mm
653230-01 CT 6002 640 g 6002 DC 5 V (±5 %) DIADUR phase grating graduation on Zerodur glass ceramic ≥ +10 °C D-sub connector, 2-row, with locking screws, with integrated electronics, coated, male, 15-pin ± 0.1 µm (at 19 °C to 21 °C) ≤ 120 mA incremental ≤ 100 m/s² IP 50 (EN 60529) Incremental length gauges with ball-bush guided plunger PUR Ø 4.5 mm 1.5 m CT 2D D330979 01 HEIDENHAIN +10/+40 °C 11 µApp 0.1 µm one (1.7 mm below upper stop) 60 mm Screw-on surface 4 µm w/o cable HEIDENHAIN-CERTO ≤ 30 m 20 °C ≤ +40 °C ≤ 1000 m/s² 2 µm ball guide via coupling with moving machine part any ± 0.02 µm ≤ 0.5 N ≤ 24 m/min .. none .. w/o cable
231011-03 MT 12W 400 g 12W DC 5 V (±5 %) DIADUR graduation on glass ≥ +10 °C Connector M23, male, 9-pin ± 1 µm ≤ 70 mA incremental ≤ 100 m/s² IP 64 (EN 60529) Incremental length gauges with plain-bush guided plunger PUR Ø 4.5 mm 1.5 m MT 04 D295051 01 HEIDENHAIN +10/+40 °C 11 µApp 1 µm one (5 mm below upper stop) 12 mm Screw-on surface 10 µm HEIDENHAIN-METRO ≤ 30 m 20 °C ≤ +50 °C ≤ 1000 m/s² 10 µm sliding glide by measured object or applying negative pressure (0,8 bar absolute) extended (by spring) any ± 0.1 µm ≤ 0.2 N ≤ 60 m/min .. none ≤ 0.2 bar
231013-03 MT 25W 500 g 25W DC 5 V (±5 %) DIADUR graduation on glass ≥ +10 °C Connector M23, male, 9-pin ± 1 µm ≤ 70 mA incremental ≤ 100 m/s² IP 64 (EN 60529) Incremental length gauges with plain-bush guided plunger PUR Ø 4.5 mm 1.5 m MT 04 D295051 01 HEIDENHAIN +10/+40 °C 11 µApp 1 µm one (5 mm below upper stop) 25 mm Screw-on surface 10 µm HEIDENHAIN-METRO ≤ 30 m 20 °C ≤ +50 °C ≤ 1000 m/s² 10 µm sliding glide by measured object or applying negative pressure (0,8 bar absolute) extended (by spring) any ± 0.1 µm ≤ 0.2 N ≤ 60 m/min .. none ≤ 0.2 bar
232714-02 MT 12P 250 g 12P DC 5 V (±5 %) DIADUR graduation on glass ≥ +10 °C Connector M23, male, 9-pin ± 0.5 µm ≤ 70 mA incremental ≤ 100 m/s² IP 50 (EN 60529) Incremental length gauges with plain-bush guided plunger PUR Ø 4.5 mm 1.5 m MT 04 D295051 01 HEIDENHAIN +10/+40 °C 11 µApp 0.5 µm one (5 mm below upper stop) 12 mm Clamping shank D = 8 mm 10 µm HEIDENHAIN-METRO ≤ 30 m 20 °C ≤ +50 °C ≤ 1000 m/s² 10 µm sliding glide pneumatic retracted (by spring) any ± 0.1 µm ≤ 0.2 N ≤ 60 m/min .. none ≤ 2.2 bar
232715-03 MT 25P 300 g 25P DC 5 V (±5 %) DIADUR graduation on glass ≥ +10 °C Connector M23, male, 9-pin ± 0.5 µm ≤ 70 mA incremental ≤ 100 m/s² IP 50 (EN 60529) Incremental length gauges with plain-bush guided plunger PUR Ø 4.5 mm 1.5 m MT 04 D295051 01 HEIDENHAIN +10/+40 °C 11 µApp 0.5 µm one (5 mm below upper stop) 25 mm Clamping shank D = 8 mm 10 µm HEIDENHAIN-METRO ≤ 30 m 20 °C ≤ +50 °C ≤ 1000 m/s² 10 µm sliding glide pneumatic retracted (by spring) any ± 0.1 µm ≤ 0.2 N ≤ 60 m/min .. none ≤ 1.2 bar
243602-01 MT 12 120 g 12 DC 5 V (±5 %) DIADUR graduation on glass ≥ +10 °C Connector M23, male, 9-pin ± 0.5 µm ≤ 70 mA incremental ≤ 100 m/s² IP 50 (EN 60529) Incremental length gauges with plain-bush guided plunger PUR Ø 4.5 mm 1.5 m MT 04 D295051 01 HEIDENHAIN +10/+40 °C 11 µApp 0.5 µm one (5 mm below upper stop) 12 mm Clamping shank D = 8 mm 10 µm HEIDENHAIN-METRO ≤ 30 m 20 °C ≤ +50 °C ≤ 1000 m/s² 10 µm sliding glide by cable lifter or measured object extended (by spring) any ± 0.1 µm ≤ 0.2 N ≤ 60 m/min 0002 Lifter included in delivery
243602-06 MT 12 120 g 12 DC 5 V (±5 %) DIADUR graduation on glass ≥ +10 °C Connector M23, male, 9-pin ± 0.5 µm ≤ 70 mA incremental ≤ 100 m/s² IP 50 (EN 60529) Incremental length gauges with plain-bush guided plunger PUR Ø 4.5 mm 1.5 m MT 04 D295051 01 HEIDENHAIN +10/+40 °C 11 µApp 0.5 µm one (5 mm below upper stop) 12 mm Clamping shank D = 8 mm 10 µm HEIDENHAIN-METRO ≤ 30 m 20 °C ≤ +50 °C ≤ 1000 m/s² 10 µm sliding glide by cable lifter or measured object extended (by spring) any ± 0.1 µm ≤ 0.2 N ≤ 60 m/min .. none
243602-16 MT 12B 120 g 12B DC 5 V (±5 %) DIADUR graduation on glass ≥ +10 °C Connector M23, male, 9-pin ± 0.5 µm ≤ 70 mA incremental ≤ 100 m/s² IP 50 (EN 60529) Incremental length gauges with ball-bush guided plunger PUR Ø 4.5 mm 1.5 m MT 04 D295051 01 HEIDENHAIN +10/+40 °C 11 µApp 0.5 µm one (5 mm below upper stop) 12 mm Clamping shank D = 8 mm 10 µm HEIDENHAIN-METRO ≤ 30 m 20 °C ≤ +50 °C ≤ 1000 m/s² 10 µm ball guide by cable lifter or measured object extended (by spring) any ± 0.1 µm ≤ 0.8 N ≤ 60 m/min .. none
243602-17 MT 12B 120 g 12B DC 5 V (±5 %) DIADUR graduation on glass ≥ +10 °C Connector M23, male, 9-pin ± 0.5 µm ≤ 70 mA incremental ≤ 100 m/s² IP 50 (EN 60529) Incremental length gauges with ball-bush guided plunger PUR Ø 4.5 mm 1.5 m MT 04 D295051 01 HEIDENHAIN +10/+40 °C 11 µApp 0.5 µm one (5 mm below upper stop) 12 mm Clamping shank D = 8 mm 10 µm HEIDENHAIN-METRO ≤ 30 m 20 °C ≤ +50 °C ≤ 1000 m/s² 10 µm ball guide by cable lifter or measured object extended (by weight) vertically downward ± 0.1 µm ≤ 0.8 N ≤ 60 m/min .. none
243603-01 MT 25 200 g 25 DC 5 V (±5 %) DIADUR graduation on glass ≥ +10 °C Connector M23, male, 9-pin ± 0.5 µm ≤ 70 mA incremental ≤ 100 m/s² IP 50 (EN 60529) Incremental length gauges with plain-bush guided plunger PUR Ø 4.5 mm 1.5 m MT 04 D295051 01 HEIDENHAIN +10/+40 °C 11 µApp 0.5 µm one (5 mm below upper stop) 25 mm Clamping shank D = 8 mm 10 µm HEIDENHAIN-METRO ≤ 30 m 20 °C ≤ +50 °C ≤ 1000 m/s² 10 µm sliding glide by cable lifter or measured object extended (by spring) any ± 0.1 µm ≤ 0.2 N ≤ 60 m/min 0002 Lifter included in delivery
243603-07 MT 25 200 g 25 DC 5 V (±5 %) DIADUR graduation on glass ≥ +10 °C Connector M23, male, 9-pin ± 0.5 µm ≤ 70 mA incremental ≤ 100 m/s² IP 50 (EN 60529) Incremental length gauges with plain-bush guided plunger PUR Ø 4.5 mm 1.5 m MT 04 D295051 01 HEIDENHAIN +10/+40 °C 11 µApp 0.5 µm one (5 mm below upper stop) 25 mm Clamping shank D = 8 mm 10 µm HEIDENHAIN-METRO ≤ 30 m 20 °C ≤ +50 °C ≤ 1000 m/s² 10 µm sliding glide by cable lifter or measured object extended (by spring) any ± 0.1 µm ≤ 0.2 N ≤ 60 m/min .. none
243603-16 MT 25B 200 g 25B DC 5 V (±5 %) DIADUR graduation on glass ≥ +10 °C Connector M23, male, 9-pin ± 0.5 µm ≤ 70 mA incremental ≤ 100 m/s² IP 50 (EN 60529) Incremental length gauges with ball-bush guided plunger PUR Ø 4.5 mm 1.5 m MT 04 D295051 01 HEIDENHAIN +10/+40 °C 11 µApp 0.5 µm one (5 mm below upper stop) 25 mm Clamping shank D = 8 mm 10 µm HEIDENHAIN-METRO ≤ 30 m 20 °C ≤ +50 °C ≤ 1000 m/s² 10 µm ball guide by cable lifter or measured object extended (by spring) any ± 0.1 µm ≤ 0.8 N ≤ 60 m/min .. none
243603-17 MT 25B 200 g 25B DC 5 V (±5 %) DIADUR graduation on glass ≥ +10 °C Connector M23, male, 9-pin ± 0.5 µm ≤ 70 mA incremental ≤ 100 m/s² IP 50 (EN 60529) Incremental length gauges with ball-bush guided plunger PUR Ø 4.5 mm 1.5 m MT 04 D295051 01 HEIDENHAIN +10/+40 °C 11 µApp 0.5 µm one (5 mm below upper stop) 25 mm Clamping shank D = 8 mm 10 µm HEIDENHAIN-METRO ≤ 30 m 20 °C ≤ +50 °C ≤ 1000 m/s² 10 µm ball guide by cable lifter or measured object extended (by weight) vertically downward ± 0.1 µm ≤ 0.8 N ≤ 60 m/min .. none
329350-02 MT 1201 100 g 1201 DC 5 V (±5 %) DIADUR phase grating graduation on Zerodur glass ceramic ≥ +10 °C Connector M23, male, 9-pin ± 0.2 µm ≤ 25 mA incremental ≤ 100 m/s² IP 50 (EN 60529) Incremental length gauges with ball-bush guided plunger PUR Ø 4.5 mm 1.5 m MT 04 D295051 01 HEIDENHAIN +10/+40 °C 11 µApp 0.2 µm one (1.7 mm below upper stop) 12 mm Clamping shank D = 8 mm 4 µm HEIDENHAIN-METRO ≤ 30 m 20 °C ≤ +40 °C ≤ 1000 m/s² 2 µm ball guide by cable lifter or measured object extended (by spring) any ± 0.02 µm ≤ 0.8 N .. none ≤ 30 m/min
329350-03 MT 1201 100 g 1201 DC 5 V (±5 %) DIADUR phase grating graduation on Zerodur glass ceramic ≥ +10 °C Connector M23, male, 9-pin ± 0.2 µm ≤ 25 mA incremental ≤ 100 m/s² IP 50 (EN 60529) Incremental length gauges with ball-bush guided plunger PUR Ø 4.5 mm 1.5 m MT 04 D295051 01 HEIDENHAIN +10/+40 °C 11 µApp 0.2 µm one (1.7 mm below upper stop) 12 mm Clamping shank D = 8 mm 4 µm HEIDENHAIN-METRO ≤ 30 m 20 °C ≤ +40 °C ≤ 1000 m/s² 2 µm ball guide by cable lifter or measured object extended (by weight) vertically downward ± 0.02 µm ≤ 0.8 N .. none ≤ 30 m/min
329351-02 MT 2501 180 g 2501 DC 5 V (±5 %) DIADUR phase grating graduation on Zerodur glass ceramic ≥ +10 °C Connector M23, male, 9-pin ± 0.2 µm ≤ 25 mA incremental ≤ 100 m/s² IP 50 (EN 60529) Incremental length gauges with ball-bush guided plunger PUR Ø 4.5 mm 1.5 m MT 04 D295051 01 HEIDENHAIN +10/+40 °C 11 µApp 0.2 µm one (1.7 mm below upper stop) 25 mm Clamping shank D = 8 mm 4 µm HEIDENHAIN-METRO ≤ 30 m 20 °C ≤ +40 °C ≤ 1000 m/s² 2 µm ball guide by cable lifter or measured object extended (by spring) any ± 0.02 µm ≤ 0.8 N .. none ≤ 30 m/min
329351-03 MT 2501 180 g 2501 DC 5 V (±5 %) DIADUR phase grating graduation on Zerodur glass ceramic ≥ +10 °C Connector M23, male, 9-pin ± 0.2 µm ≤ 25 mA incremental ≤ 100 m/s² IP 50 (EN 60529) Incremental length gauges with ball-bush guided plunger PUR Ø 4.5 mm 1.5 m MT 04 D295051 01 HEIDENHAIN +10/+40 °C 11 µApp 0.2 µm one (1.7 mm below upper stop) 25 mm Clamping shank D = 8 mm 4 µm HEIDENHAIN-METRO ≤ 30 m 20 °C ≤ +40 °C ≤ 1000 m/s² 2 µm ball guide by cable lifter or measured object extended (by weight) vertically downward ± 0.02 µm ≤ 0.8 N .. none ≤ 30 m/min
331314-02 MT 1281 100 g 1281 DC 5 V (±5 %) DIADUR phase grating graduation on Zerodur glass ceramic ≥ +10 °C Connector M23, male, 12-pin ± 0.2 µm ≤ 130 mA incremental ≤ 100 m/s² IP 50 (EN 60529) Incremental length gauges with ball-bush guided plunger PUR Ø 4.5 mm 1.5 m MT 03 D294999 01 HEIDENHAIN +10/+40 °C 1 Vpp 0.2 µm one (1.7 mm below upper stop) 12 mm Clamping shank D = 8 mm 4 µm HEIDENHAIN-METRO ≤ 30 m 20 °C ≤ +40 °C ≤ 1000 m/s² 2 µm ball guide by cable lifter or measured object extended (by spring) any ± 0.02 µm ≤ 0.8 N .. none ≤ 30 m/min
331314-03 MT 1281 100 g 1281 DC 5 V (±5 %) DIADUR phase grating graduation on Zerodur glass ceramic ≥ +10 °C Connector M23, male, 12-pin ± 0.2 µm ≤ 130 mA incremental ≤ 100 m/s² IP 50 (EN 60529) Incremental length gauges with ball-bush guided plunger PUR Ø 4.5 mm 1.5 m MT 03 D294999 01 HEIDENHAIN +10/+40 °C 1 Vpp 0.2 µm one (1.7 mm below upper stop) 12 mm Clamping shank D = 8 mm 4 µm HEIDENHAIN-METRO ≤ 30 m 20 °C ≤ +40 °C ≤ 1000 m/s² 2 µm ball guide by cable lifter or measured object extended (by weight) vertically downward ± 0.02 µm ≤ 0.8 N .. none ≤ 30 m/min
332104-02 MT 2581 180 g 2581 DC 5 V (±5 %) DIADUR phase grating graduation on Zerodur glass ceramic ≥ +10 °C Connector M23, male, 12-pin ± 0.2 µm ≤ 130 mA incremental ≤ 100 m/s² IP 50 (EN 60529) Incremental length gauges with ball-bush guided plunger PUR Ø 4.5 mm 1.5 m MT 03 D294999 01 HEIDENHAIN +10/+40 °C 1 Vpp 0.2 µm one (1.7 mm below upper stop) 25 mm Clamping shank D = 8 mm 4 µm HEIDENHAIN-METRO ≤ 30 m 20 °C ≤ +40 °C ≤ 1000 m/s² 2 µm ball guide by cable lifter or measured object extended (by spring) any ± 0.02 µm ≤ 0.8 N .. none ≤ 30 m/min
332104-03 MT 2581 180 g 2581 DC 5 V (±5 %) DIADUR phase grating graduation on Zerodur glass ceramic ≥ +10 °C Connector M23, male, 12-pin ± 0.2 µm ≤ 130 mA incremental ≤ 100 m/s² IP 50 (EN 60529) Incremental length gauges with ball-bush guided plunger PUR Ø 4.5 mm 1.5 m MT 03 D294999 01 HEIDENHAIN +10/+40 °C 1 Vpp 0.2 µm one (1.7 mm below upper stop) 25 mm Clamping shank D = 8 mm 4 µm HEIDENHAIN-METRO ≤ 30 m 20 °C ≤ +40 °C ≤ 1000 m/s² 2 µm ball guide by cable lifter or measured object extended (by weight) vertically downward ± 0.02 µm ≤ 0.8 N .. none ≤ 30 m/min
359355-02 MT 1281 100 g 1281 DC 5 V (±5 %) DIADUR phase grating graduation on Zerodur glass ceramic ≥ +10 °C D-sub connector, 2-row, with locking screws, with integrated electronics, coated, male, 15-pin ± 0.2 µm ≤ 130 mA incremental ≤ 100 m/s² IP 50 (EN 60529) Incremental length gauges with ball-bush guided plunger PUR Ø 4.5 mm 1.5 m MT 0V D330978 01 HEIDENHAIN +10/+40 °C 1 Vpp 0.2 µm one (1.7 mm below upper stop) 12 mm Clamping shank D = 8 mm 4 µm HEIDENHAIN-METRO ≤ 30 m 20 °C ≤ +40 °C ≤ 1000 m/s² 2 µm ball guide by cable lifter or measured object extended (by spring) any ± 0.02 µm ≤ 0.8 N .. none ≤ 30 m/min
359355-03 MT 1281MG 100 g 1281MG DC 5 V (±5 %) DIADUR phase grating graduation on Zerodur glass ceramic ≥ +10 °C D-sub connector, 2-row, with locking screws, with integrated electronics, coated, male, 15-pin ± 0.2 µm ≤ 130 mA incremental ≤ 100 m/s² IP 50 (EN 60529) Incremental length gauges with ball-bush guided plunger PUR Ø 4.5 mm 1.5 m MT 0V D330978 01 HEIDENHAIN +10/+40 °C 1 Vpp 0.2 µm one (1.7 mm below upper stop) 12 mm Clamping shank D = 8 mm 4 µm HEIDENHAIN-METRO ≤ 30 m 20 °C ≤ +40 °C ≤ 1000 m/s² 2 µm ball guide by cable lifter or measured object extended (by weight) vertically downward ± 0.02 µm ≤ 0.8 N .. none ≤ 30 m/min
359355-10 MT 1281MW 100 g 1281MW DC 5 V (±5 %) DIADUR phase grating graduation on Zerodur glass ceramic ≥ +10 °C D-sub connector, 2-row, with locking screws, with integrated electronics, coated, male, 15-pin ± 0.2 µm ≤ 130 mA incremental ≤ 100 m/s² IP 50 (EN 60529) Incremental length gauges with ball-bush guided plunger PUR Ø 4.5 mm 1.5 m MT 0V D330978 01 HEIDENHAIN +10/+40 °C 1 Vpp 0.2 µm one (1.7 mm below upper stop) 12 mm Clamping shank D = 8 mm 4 µm HEIDENHAIN-METRO ≤ 30 m 20 °C ≤ +40 °C ≤ 1000 m/s² 2 µm ball guide by cable lifter or measured object extended (by spring) vertically downward ± 0.02 µm ≤ 0.8 N 0018 Gauging force <0.1 N ≤ 30 m/min
359355-11 MT 1281MR 100 g 1281MR DC 5 V (±5 %) DIADUR phase grating graduation on Zerodur glass ceramic ≥ +10 °C D-sub connector, 2-row, with locking screws, with integrated electronics, coated, male, 15-pin ± 0.2 µm ≤ 130 mA incremental ≤ 100 m/s² IP 50 (EN 60529) Incremental length gauges with ball-bush guided plunger PUR Ø 4.5 mm 1.5 m MT 0V D330978 01 HEIDENHAIN +10/+40 °C 1 Vpp 0.2 µm one (1.7 mm below upper stop) 12 mm Clamping shank D = 8 mm 4 µm HEIDENHAIN-METRO ≤ 30 m 20 °C ≤ +40 °C ≤ 1000 m/s² 2 µm ball guide by cable lifter or measured object extended (by spring) any ± 0.02 µm ≤ 0.8 N 0024 Gauging force 0.2 - 0.3 N ≤ 30 m/min
363409-02 MT 2581 180 g 2581 DC 5 V (±5 %) DIADUR phase grating graduation on Zerodur glass ceramic ≥ +10 °C D-sub connector, 2-row, with locking screws, with integrated electronics, coated, male, 15-pin ± 0.2 µm ≤ 130 mA incremental ≤ 100 m/s² IP 50 (EN 60529) Incremental length gauges with ball-bush guided plunger PUR Ø 4.5 mm 1.5 m MT 0V D330978 01 HEIDENHAIN +10/+40 °C 1 Vpp 0.2 µm one (1.7 mm below upper stop) 25 mm Clamping shank D = 8 mm 4 µm HEIDENHAIN-METRO ≤ 30 m 20 °C ≤ +40 °C ≤ 1000 m/s² 2 µm ball guide by cable lifter or measured object extended (by spring) any ± 0.02 µm ≤ 0.8 N .. none ≤ 30 m/min
363409-03 MT 2581 180 g 2581 DC 5 V (±5 %) DIADUR phase grating graduation on Zerodur glass ceramic ≥ +10 °C D-sub connector, 2-row, with locking screws, with integrated electronics, coated, male, 15-pin ± 0.2 µm ≤ 130 mA incremental ≤ 100 m/s² IP 50 (EN 60529) Incremental length gauges with ball-bush guided plunger PUR Ø 4.5 mm 1.5 m MT 0V D330978 01 HEIDENHAIN +10/+40 °C 1 Vpp 0.2 µm one (1.7 mm below upper stop) 25 mm Clamping shank D = 8 mm 4 µm HEIDENHAIN-METRO ≤ 30 m 20 °C ≤ +40 °C ≤ 1000 m/s² 2 µm ball guide by cable lifter or measured object extended (by weight) vertically downward ± 0.02 µm ≤ 0.8 N .. none ≤ 30 m/min
372495-01 MT 2587 190 g 2587 DC 5 V (±5 %) DIADUR phase grating graduation on Zerodur glass ceramic ≥ +10 °C Connector M23, male, 12-pin ± 0.2 µm ≤ 130 mA incremental ≤ 100 m/s² IP 64 (EN 60529) Incremental length gauges with ball-bush guided plunger PUR Ø 4.5 mm 1.5 m MT 03 D294999 01 HEIDENHAIN +10/+40 °C 1 Vpp 0.2 µm one (1.7 mm below upper stop) 25 mm Clamping shank D = 8 mm 4 µm HEIDENHAIN-METRO ≤ 30 m 20 °C ≤ +40 °C ≤ 1000 m/s² 2 µm ball guide pneumatic retracted (by spring) any ± 0.02 µm ≤ 0.8 N .. none ≤ 1.4 bar ≤ 30 m/min
375162-01 MT 1287 110 g 1287 DC 5 V (±5 %) DIADUR phase grating graduation on Zerodur glass ceramic ≥ +10 °C Connector M23, male, 12-pin ± 0.2 µm ≤ 130 mA incremental ≤ 100 m/s² IP 64 (EN 60529) Incremental length gauges with ball-bush guided plunger PUR Ø 4.5 mm 1.5 m MT 03 D294999 01 HEIDENHAIN +10/+40 °C 1 Vpp 0.2 µm one (1.7 mm below upper stop) 12 mm Clamping shank D = 8 mm 4 µm HEIDENHAIN-METRO ≤ 30 m 20 °C ≤ +40 °C ≤ 1000 m/s² 2 µm ball guide pneumatic retracted (by spring) any ± 0.02 µm ≤ 0.8 N .. none ≤ 1.4 bar ≤ 30 m/min
376990-01 MT 1287 110 g 1287 DC 5 V (±5 %) DIADUR phase grating graduation on Zerodur glass ceramic ≥ +10 °C D-sub connector, 2-row, with locking screws, with integrated electronics, coated, male, 15-pin ± 0.2 µm ≤ 130 mA incremental ≤ 100 m/s² IP 64 (EN 60529) Incremental length gauges with ball-bush guided plunger PUR Ø 4.5 mm 1.5 m MT 0V D330978 01 HEIDENHAIN +10/+40 °C 1 Vpp 0.2 µm one (1.7 mm below upper stop) 12 mm Clamping shank D = 8 mm 4 µm HEIDENHAIN-METRO ≤ 30 m 20 °C ≤ +40 °C ≤ 1000 m/s² 2 µm ball guide pneumatic retracted (by spring) any ± 0.02 µm ≤ 0.8 N .. none ≤ 1.4 bar ≤ 30 m/min
376992-01 MT 2587 190 g 2587 DC 5 V (±5 %) DIADUR phase grating graduation on Zerodur glass ceramic ≥ +10 °C D-sub connector, 2-row, with locking screws, with integrated electronics, coated, male, 15-pin ± 0.2 µm ≤ 130 mA incremental ≤ 100 m/s² IP 50 (EN 60529) Incremental length gauges with ball-bush guided plunger PUR Ø 4.5 mm 1.5 m MT 0V D330978 01 HEIDENHAIN +10/+40 °C 1 Vpp 0.2 µm one (1.7 mm below upper stop) 25 mm Clamping shank D = 8 mm 4 µm HEIDENHAIN-METRO ≤ 30 m 20 °C ≤ +40 °C ≤ 1000 m/s² 2 µm ball guide pneumatic retracted (by spring) any ± 0.02 µm ≤ 0.8 N .. none ≤ 1.4 bar ≤ 30 m/min
331666-01 MT 1271 100 g 1271 DC 5 V (±10 %) DIADUR phase grating graduation on Zerodur glass ceramic ≥ +10 °C D-sub connector, 2-row, with locking screws, with integrated electronics, coated, male, 15-pin ± 0.2 µm ≤ 160 mA incremental ≤ 100 m/s² IP 50 (EN 60529) Incremental length gauges with ball-bush guided plunger PUR Ø 4.5 mm 1.5 m MT 0V D330978 OT for disturbance LOW 100 kHz 01 HEIDENHAIN +10/+40 °C TTL 0.2 µm one (1.7 mm below upper stop) 12 mm 4 µm 90° HEIDENHAIN-METRO ≤ 30 m 20 °C ≤ +40 °C ≤ 1000 m/s² 0.4 µm ball guide by cable lifter or measured object extended (by spring) any ± 0.02 µm ≤ 0.8 N ≤ 12 m/min .. none ≥ 0.48 µs ≤ 30 m/min
331666-02 MT 1271 100 g 1271 DC 5 V (±10 %) DIADUR phase grating graduation on Zerodur glass ceramic ≥ +10 °C D-sub connector, 2-row, with locking screws, with integrated electronics, coated, male, 15-pin ± 0.2 µm ≤ 160 mA incremental ≤ 100 m/s² IP 50 (EN 60529) Incremental length gauges with ball-bush guided plunger PUR Ø 4.5 mm 1.5 m MT 0V D330978 OT for disturbance LOW 100 kHz 01 HEIDENHAIN +10/+40 °C TTL 0.2 µm one (1.7 mm below upper stop) 12 mm 4 µm 90° HEIDENHAIN-METRO ≤ 30 m 20 °C ≤ +40 °C ≤ 1000 m/s² 0.4 µm ball guide by cable lifter or measured object extended (by weight) vertically downward ± 0.02 µm ≤ 0.8 N ≤ 12 m/min .. none ≥ 0.48 µs ≤ 30 m/min
331666-04 MT 1271 100 g 1271 DC 5 V (±10 %) DIADUR phase grating graduation on Zerodur glass ceramic ≥ +10 °C D-sub connector, 2-row, with locking screws, with integrated electronics, coated, male, 15-pin ± 0.2 µm ≤ 160 mA incremental ≤ 100 m/s² IP 50 (EN 60529) Incremental length gauges with ball-bush guided plunger PUR Ø 4.5 mm 1.5 m MT 0V D330978 MT for disturbance Ua1/Ua2 high-impedance 50 kHz 01 HEIDENHAIN +10/+40 °C TTL 0.2 µm one (1.7 mm below upper stop) 12 mm 4 µm 90° HEIDENHAIN-METRO ≤ 30 m 20 °C ≤ +40 °C ≤ 1000 m/s² 0.4 µm ball guide by cable lifter or measured object extended (by weight) any ± 0.02 µm ≤ 0.8 N ≤ 12 m/min .. none ≥ 0.23 µs ≤ 30 m/min
331666-05 MT 1271 100 g 1271 DC 5 V (±10 %) DIADUR phase grating graduation on Zerodur glass ceramic ≥ +10 °C D-sub connector, 2-row, with locking screws, with integrated electronics, coated, male, 15-pin ± 0.2 µm ≤ 160 mA incremental ≤ 100 m/s² IP 50 (EN 60529) Incremental length gauges with ball-bush guided plunger PUR Ø 4.5 mm 1.5 m MT 0V D330978 MT for disturbance Ua1/Ua2 high-impedance 200 kHz 01 HEIDENHAIN +10/+40 °C TTL 0.2 µm one (1.7 mm below upper stop) 12 mm 4 µm 90° HEIDENHAIN-METRO ≤ 30 m 20 °C ≤ +40 °C ≤ 1000 m/s² 0.4 µm ball guide by cable lifter or measured object extended (by spring) any ± 0.02 µm ≤ 0.8 N ≤ 24 m/min .. none ≥ 0.23 µs ≤ 30 m/min
331666-06 MT 1271 100 g 1271 DC 5 V (±10 %) DIADUR phase grating graduation on Zerodur glass ceramic ≥ +10 °C D-sub connector, 2-row, with locking screws, with integrated electronics, coated, male, 15-pin ± 0.2 µm ≤ 160 mA incremental ≤ 100 m/s² IP 50 (EN 60529) Incremental length gauges with ball-bush guided plunger PUR Ø 4.5 mm 1.5 m MT 0V D330978 OT for disturbance LOW 50 kHz 01 HEIDENHAIN +10/+40 °C TTL 0.2 µm one (1.7 mm below upper stop) 12 mm 4 µm 90° HEIDENHAIN-METRO ≤ 30 m 20 °C ≤ +40 °C ≤ 1000 m/s² 0.2 µm ball guide by cable lifter or measured object extended (by spring) any ± 0.02 µm ≤ 0.8 N ≤ 6 m/min .. none ≥ 0.48 µs ≤ 30 m/min
331666-51 MT 1271 100 g 1271 DC 5 V (±10 %) DIADUR phase grating graduation on Zerodur glass ceramic ≥ +10 °C D-sub connector, 2-row, with locking screws, with integrated electronics, coated, male, 15-pin ± 0.2 µm ≤ 160 mA incremental ≤ 100 m/s² IP 50 (EN 60529) Incremental length gauges with ball-bush guided plunger PUR Ø 4.5 mm 1.5 m MT 0V D330978 OT for disturbance LOW 100 kHz 01 HEIDENHAIN +10/+40 °C TTL 0.2 µm one (1.7 mm below upper stop) 12 mm 4 µm 90° HEIDENHAIN-METRO ≤ 30 m 20 °C ≤ +40 °C ≤ 1000 m/s² 0.2 µm ball guide by cable lifter or measured object extended (by spring) any ± 0.02 µm ≤ 0.8 N ≤ 12 m/min .. none ≥ 0.23 µs ≤ 30 m/min
331666-52 MT 1271 100 g 1271 DC 5 V (±10 %) DIADUR phase grating graduation on Zerodur glass ceramic ≥ +10 °C D-sub connector, 2-row, with locking screws, with integrated electronics, coated, male, 15-pin ± 0.2 µm ≤ 160 mA incremental ≤ 100 m/s² IP 50 (EN 60529) Incremental length gauges with ball-bush guided plunger PUR Ø 4.5 mm 1.5 m MT 0V D330978 OT for disturbance LOW 100 kHz 01 HEIDENHAIN +10/+40 °C TTL 0.2 µm one (1.7 mm below upper stop) 12 mm 4 µm 90° HEIDENHAIN-METRO ≤ 30 m 20 °C ≤ +40 °C ≤ 1000 m/s² 0.2 µm ball guide by cable lifter or measured object extended (by weight) vertically downward ± 0.02 µm ≤ 0.8 N ≤ 12 m/min .. none ≥ 0.23 µs ≤ 30 m/min
331666-S1 MT 1271 100 g 1271 DC 5 V (±10 %) DIADUR phase grating graduation on Zerodur glass ceramic ≥ +10 °C D-sub connector, 2-row, with locking screws, with integrated electronics, coated, male, 15-pin ± 0.2 µm ≤ 160 mA incremental ≤ 100 m/s² IP 50 (EN 60529) Incremental length gauges with ball-bush guided plunger PUR Ø 4.5 mm 1.5 m MT 0V D330978 OT for disturbance LOW 50 kHz 01 HEIDENHAIN +10/+40 °C TTL 0.2 µm one (1.7 mm below upper stop) 12 mm 4 µm 90° HEIDENHAIN-METRO ≤ 30 m 20 °C ≤ +40 °C ≤ 1000 m/s² 0.4 µm ball guide by cable lifter or measured object extended (by spring) any ± 0.02 µm ≤ 0.8 N ≤ 6 m/min .. none ≥ 0.98 µs ≤ 30 m/min
331667-01 MT 2571 180 g 2571 DC 5 V (±10 %) DIADUR phase grating graduation on Zerodur glass ceramic ≥ +10 °C D-sub connector, 2-row, with locking screws, with integrated electronics, coated, male, 15-pin ± 0.2 µm ≤ 160 mA incremental ≤ 100 m/s² IP 50 (EN 60529) Incremental length gauges with ball-bush guided plunger PUR Ø 4.5 mm 1.5 m MT 0V D330978 OT for disturbance LOW 100 kHz 01 HEIDENHAIN +10/+40 °C TTL 0.2 µm one (1.7 mm below upper stop) 25 mm 4 µm 90° HEIDENHAIN-METRO ≤ 30 m 20 °C ≤ +40 °C ≤ 1000 m/s² 0.4 µm ball guide by cable lifter or measured object extended (by spring) any ± 0.02 µm ≤ 0.8 N ≤ 12 m/min .. none ≥ 0.48 µs ≤ 30 m/min
331667-02 MT 2571 180 g 2571 DC 5 V (±10 %) DIADUR phase grating graduation on Zerodur glass ceramic ≥ +10 °C D-sub connector, 2-row, with locking screws, with integrated electronics, coated, male, 15-pin ± 0.2 µm ≤ 160 mA incremental ≤ 100 m/s² IP 50 (EN 60529) Incremental length gauges with ball-bush guided plunger PUR Ø 4.5 mm 1.5 m MT 0V D330978 OT for disturbance LOW 100 kHz 01 HEIDENHAIN +10/+40 °C TTL 0.2 µm one (1.7 mm below upper stop) 25 mm 4 µm 90° HEIDENHAIN-METRO ≤ 30 m 20 °C ≤ +40 °C ≤ 1000 m/s² 0.4 µm ball guide by cable lifter or measured object extended (by weight) vertically downward ± 0.02 µm ≤ 0.8 N ≤ 12 m/min .. none ≥ 0.48 µs ≤ 30 m/min
331667-03 MT 2571 180 g 2571 DC 5 V (±10 %) DIADUR phase grating graduation on Zerodur glass ceramic ≥ +10 °C D-sub connector, 2-row, with locking screws, with integrated electronics, coated, male, 15-pin ± 0.2 µm ≤ 160 mA incremental ≤ 100 m/s² IP 50 (EN 60529) Incremental length gauges with ball-bush guided plunger PUR Ø 4.5 mm 1.5 m MT 0V D330978 OT for disturbance LOW 200 kHz 01 HEIDENHAIN +10/+40 °C TTL 0.2 µm one (1.7 mm below upper stop) 25 mm 4 µm 90° HEIDENHAIN-METRO ≤ 30 m 20 °C ≤ +40 °C ≤ 1000 m/s² 0.4 µm ball guide by cable lifter or measured object extended (by spring) any ± 0.02 µm ≤ 0.8 N ≤ 24 m/min .. none ≥ 0.23 µs ≤ 30 m/min
331667-05 MT 2571 180 g 2571 DC 5 V (±10 %) DIADUR phase grating graduation on Zerodur glass ceramic ≥ +10 °C D-sub connector, 2-row, with locking screws, with integrated electronics, coated, male, 15-pin ± 0.2 µm ≤ 160 mA incremental ≤ 100 m/s² IP 50 (EN 60529) Incremental length gauges with ball-bush guided plunger PUR Ø 4.5 mm 1.5 m MT 0V D330978 OT for disturbance LOW 50 kHz 01 HEIDENHAIN +10/+40 °C TTL 0.2 µm one (1.7 mm below upper stop) 25 mm 4 µm 90° HEIDENHAIN-METRO ≤ 30 m 20 °C ≤ +40 °C ≤ 1000 m/s² 0.4 µm ball guide by cable lifter or measured object extended (by spring) any ± 0.02 µm ≤ 0.8 N ≤ 6 m/min .. none ≥ 0.98 µs ≤ 30 m/min
331667-07 MT 2571 180 g 2571 DC 5 V (±10 %) DIADUR phase grating graduation on Zerodur glass ceramic ≥ +10 °C D-sub connector, 2-row, with locking screws, with integrated electronics, coated, male, 15-pin ± 0.2 µm ≤ 160 mA incremental ≤ 100 m/s² IP 50 (EN 60529) Incremental length gauges with ball-bush guided plunger PUR Ø 4.5 mm 1.5 m MT 0V D330978 OT for disturbance LOW 25 kHz 01 HEIDENHAIN +10/+40 °C TTL 0.2 µm one (1.7 mm below upper stop) 25 mm 4 µm 90° HEIDENHAIN-METRO ≤ 30 m 20 °C ≤ +40 °C ≤ 1000 m/s² 0.2 µm ball guide by cable lifter or measured object extended (by spring) any ± 0.02 µm ≤ 0.8 N ≤ 12 m/min .. none ≥ 0.23 µs ≤ 30 m/min
331667-51 MT 2571 180 g 2571 DC 5 V (±10 %) DIADUR phase grating graduation on Zerodur glass ceramic ≥ +10 °C D-sub connector, 2-row, with locking screws, with integrated electronics, coated, male, 15-pin ± 0.2 µm ≤ 160 mA incremental ≤ 100 m/s² IP 50 (EN 60529) Incremental length gauges with ball-bush guided plunger PUR Ø 4.5 mm 1.5 m MT 0V D330978 OT for disturbance LOW 100 kHz 01 HEIDENHAIN +10/+40 °C TTL 0.2 µm one (1.7 mm below upper stop) 25 mm 4 µm 90° HEIDENHAIN-METRO ≤ 30 m 20 °C ≤ +40 °C ≤ 1000 m/s² 0.2 µm ball guide by cable lifter or measured object extended (by spring) any ± 0.02 µm ≤ 0.8 N ≤ 12 m/min .. none ≥ 0.23 µs ≤ 30 m/min
331667-52 MT 2571 180 g 2571 DC 5 V (±10 %) DIADUR phase grating graduation on Zerodur glass ceramic ≥ +10 °C D-sub connector, 2-row, with locking screws, with integrated electronics, coated, male, 15-pin ± 0.2 µm ≤ 160 mA incremental ≤ 100 m/s² IP 50 (EN 60529) Incremental length gauges with ball-bush guided plunger PUR Ø 4.5 mm 1.5 m MT