Scale |
LIC 4009 |
||||||
Measuring standard Coefficient of linear expansion |
Steel scale tape with absolute and incremental METALLUR track αtherm 10 · 10–6 K–1 |
||||||
Accuracy grade* |
±3 µm, ±15 µm1) |
||||||
Baseline error |
≤ ±0.750 µm/50 mm (typical) |
||||||
Measuring length (ML)* |
70 120 170 220 270 320 370 420 520 620 720 820 920 1020 |
||||||
Mass |
31 g/m |
||||||
Scanning head |
LIC 411 |
LIC 419 F |
LIC 419 M |
LIC 419 P |
LIC 419 Y |
||
Interface |
EnDat 2.2 |
Fanuc Serial Interface αi |
Mitsubishi high speed interface |
Panasonic Serial Interface |
Yaskawa Serial Interface |
||
Ordering designation* |
EnDat22 |
Fanuc05 |
Mit03-4 |
Mit02-2 |
Pana01 |
YEC07 |
|
Measuring step* |
0.01 µm (10 nm) 0.005 µm (5 nm) 0.001 µm (1 nm)2) |
||||||
Calculation time tcal Clock frequency |
≤ 5 µs ≤ 16 MHz |
– |
|||||
Traversing speed3) |
≤ 600 m/min |
||||||
Interpolation error |
±20 nm |
||||||
Electrical connection* |
Cable, 1 m or 3 m, with 8-pin M12 coupling (male) or 15-pin D-sub connector (male) |
||||||
Cable length (with HEIDENHAIN cable) |
≤ 100 m4) |
≤ 50 m |
≤ 30 m |
≤ 50 m |
|||
Supply voltage |
DC 3.6 V to 14 V |
||||||
Power consumption3) (max.) |
At 3.6 V: ≤ 700 mW At 14 V: ≤ 800 mW |
At 3.6 V: ≤ 850 mW At 14 V: ≤ 950 mW |
|||||
Current consumption (typical) |
At 5 V: 75 mA |
At 5 V: 95 mA (without load) |
|||||
Vibration 55 Hz to 2000 Hz Shock 6 ms |
≤ 500 m/s2 (EN 60068-2-6) ≤ 1000 m/s2 (EN 60068-2-27) |
||||||
Operating temperature |
–10 °C to 70 °C |
||||||
Mass Scanning head Connecting cable Connecting element |
≤ 18 g (without cable) 20 g/m M12 coupling: 15 g; D-sub connector: 32 g |
||||||
* Please select when ordering 1) ±5 µm after linear length-error compensation in the evaluation electronics 2) Mitsubishi: measuring length ≤ 2040 mm Yaskawa: measuring length ≤ 1840 mm 3) See General electrical information in the Interfaces of HEIDENHAIN Encoders brochure 4) With LIC 411 FS scanning head: clock frequency: 8 MHz |